Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • 首頁
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
  • 分類瀏覽
    • 研究成果檢索
    • 研究人員
    • 單位
    • 計畫
  • 機構典藏
  • SDGs
  • 登入
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 電機資訊學院
  3. 電機工程學系
Please use this identifier to cite or link to this item: http://scholars.ntou.edu.tw/handle/123456789/21041
DC 欄位值語言
dc.contributor.authorYen, Chih-Taen_US
dc.contributor.authorJin, Shih-Cyuanen_US
dc.date.accessioned2022-03-07T02:16:54Z-
dc.date.available2022-03-07T02:16:54Z-
dc.date.issued2022-01-01-
dc.identifier.issn0914-4935-
dc.identifier.urihttp://scholars.ntou.edu.tw/handle/123456789/21041-
dc.description.abstractA complex intraocular lens (IOL) design involving numerous uncertain variables is proposed. We integrated a genetic algorithm (GA) with a freeform surface lens by using CODE V optical design software to design a multifocal IOL for the human eye. We mainly used a freeform surface lens of acrylic material in the initial crystalline state to enhance image sensing quality; therefore, we used the internal human eye model in the software. The proposed optimization algorithm employs a GA method to optimally simulate the focusing function of the human eye; in this method, the thickness and curvature of the anterior lens and the posterior part of the IOL were varied. We performed a comparison of the proposed GA-designed IOLs and those designed using a CODE V built-in optimization algorithm for the hyperopia 300 degree condition of the human eye. When the pupil entrance was 6 mm, the proposed IOL design improved the RMS of the spot diagram by approximately 11.99 and 10.65% for the human eye to object distances of 35 cm and infinity, respectively. Moreover, the modulation transfer function (MTF) was improved by approximately 5.06 and 15.06% for distances of 35 cm and infinity at a spatial frequency of 15 cycles/mm, respectively.en_US
dc.language.isoEnglishen_US
dc.publisherMYU, SCIENTIFIC PUBLISHING DIVISIONen_US
dc.relation.ispartofSENSORS AND MATERIALSen_US
dc.subjectintraocular lens (IOL)en_US
dc.subjectthird-order aberrationsen_US
dc.subjectfreeform surface lensen_US
dc.subjectgenetic algorithm (GA)en_US
dc.titleFreeform Surface Lens Design Using Genetic Algorithm with Acrylic Material for Reducing Aberrations in Multifocal Artificial Intraocular Lens to Enhance Image Sensing Qualityen_US
dc.typejournal articleen_US
dc.identifier.doi10.18494/SAM3556-
dc.identifier.isiWOS:000748402400001-
dc.relation.journalvolume34en_US
dc.relation.journalissue1en_US
dc.relation.pages187-201en_US
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.cerifentitytypePublications-
item.fulltextno fulltext-
item.languageiso639-1English-
item.openairetypejournal article-
crisitem.author.deptNational Taiwan Ocean University,NTOU-
crisitem.author.deptDepartment of Electrical Engineering-
crisitem.author.deptCollege of Electrical Engineering and Computer Science-
crisitem.author.parentorgCollege of Electrical Engineering and Computer Science-
crisitem.author.parentorgNational Taiwan Ocean University,NTOU-
顯示於:電機工程學系
顯示文件簡單紀錄

Page view(s)

158
上周
0
上個月
3
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋