Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • Home
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
  • Explore by
    • Research Outputs
    • Researchers
    • Organizations
    • Projects
  • Communities & Collections
  • SDGs
  • Sign in
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 電機資訊學院
  3. 電機工程學系
Please use this identifier to cite or link to this item: http://scholars.ntou.edu.tw/handle/123456789/21436
DC FieldValueLanguage
dc.contributor.authorJian-Hong Liuen_US
dc.contributor.authorChia-Chi Chuen_US
dc.date.accessioned2022-04-19T05:59:32Z-
dc.date.available2022-04-19T05:59:32Z-
dc.date.issued2014-07-
dc.identifier.isbn978-1-4799-6415-4-
dc.identifier.issn1932-5517-
dc.identifier.urihttp://scholars.ntou.edu.tw/handle/123456789/21436-
dc.description.abstractThe short-term voltage instability of induction generators (IGs) is the phenomenon of the unstable high slip when the output power exceeds its maximum power transfer. As the penetration of renewable energy distributed source is increasing, the voltage stability issue of large-scale power system with the intermittent source will become increasing important. As severe voltage sags due to a fault in the network, reactive support is greatly reduced and the IG tends to over-accelerate. After voltage recovery, the rotor speed of the IG may be so high that it does not return to the pre-fault equilibrium point. In this paper, the short-term voltage instability of a bulk power grid connected with IGs will be detected by synchrophasor measurement approaches. First, by extending modified coupled single-port models derived from Thevenin equivalent circuits of the bulk power grid with multiple IGs, a synchrophasors-based voltage stability indicator is developed for fast detecting the instability of IGs. Simulation experiments on the IEEE 14-bus system have been conducted to validate the feasibility and the accuracy of the proposed method.en_US
dc.language.isoen_USen_US
dc.publisherIEEEen_US
dc.titleShort-Term Voltage Instability Detections of Wind Generators Using Synchrophasorsen_US
dc.typeconference paperen_US
dc.relation.conference2014 IEEE PES General Meeting | Conference & Exposition, National Harbor, MD, USAen_US
dc.identifier.doi10.1109/PESGM.2014.6939896-
item.fulltextno fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_5794-
item.grantfulltextnone-
item.openairetypeconference paper-
item.cerifentitytypePublications-
item.languageiso639-1en_US-
crisitem.author.deptNational Taiwan Ocean University,NTOU-
crisitem.author.deptDepartment of Electrical Engineering-
crisitem.author.deptCollege of Electrical Engineering and Computer Science-
crisitem.author.parentorgCollege of Electrical Engineering and Computer Science-
crisitem.author.parentorgNational Taiwan Ocean University,NTOU-
Appears in Collections:電機工程學系
Show simple item record

Page view(s)

80
Last Week
0
Last month
0
checked on Jun 30, 2025

Google ScholarTM

Check

Altmetric

Altmetric

Related Items in TAIR


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Explore by
  • Communities & Collections
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Build with DSpace-CRIS - Extension maintained and optimized by Logo 4SCIENCE Feedback