http://scholars.ntou.edu.tw/handle/123456789/22048
DC 欄位 | 值 | 語言 |
---|---|---|
dc.contributor.author | Yen, Chih-Ta | en_US |
dc.contributor.author | Chen, Un-Hung | en_US |
dc.contributor.author | Wang, Guo-Chang | en_US |
dc.contributor.author | Chen, Zong-Xian | en_US |
dc.date.accessioned | 2022-08-17T02:42:43Z | - |
dc.date.available | 2022-08-17T02:42:43Z | - |
dc.date.issued | 2022-06-01 | - |
dc.identifier.uri | http://scholars.ntou.edu.tw/handle/123456789/22048 | - |
dc.description.abstract | This study proposed a noninvasive blood glucose estimation system based on dual-wavelength photoplethysmography (PPG) and bioelectrical impedance measuring technology that can avoid the discomfort created by conventional invasive blood glucose measurement methods while accurately estimating blood glucose. The measured PPG signals are converted into mean, variance, skewness, kurtosis, standard deviation, and information entropy. The data obtained by bioelectrical impedance measuring consist of the real part, imaginary part, phase, and amplitude size of 11 types of frequencies, which are converted into features through principal component analyses. After combining the input of seven physiological features, the blood glucose value is finally obtained as the input of the back-propagation neural network (BPNN). To confirm the robustness of the system operation, this study collected data from 40 volunteers and established a database. From the experimental results, the system has a mean squared error of 40.736, a root mean squared error of 6.3824, a mean absolute error of 5.0896, a mean absolute relative difference of 4.4321%, and a coefficient of determination (R Squared, R-2) of 0.997, all of which fall within the clinically accurate region A in the Clarke error grid analyses. | en_US |
dc.language.iso | English | en_US |
dc.publisher | MDPI | en_US |
dc.relation.ispartof | SENSORS | en_US |
dc.subject | blood glucose estimation | en_US |
dc.subject | photoplethysmography (PPG) | en_US |
dc.subject | bioelectrical impedance | en_US |
dc.subject | principal component analysis (PCA) | en_US |
dc.subject | back-propagation neural network (BPNN) | en_US |
dc.title | Non-Invasive Blood Glucose Estimation System Based on a Neural Network with Dual-Wavelength Photoplethysmography and Bioelectrical Impedance Measuring | en_US |
dc.type | journal article | en_US |
dc.identifier.doi | 10.3390/s22124452 | - |
dc.identifier.isi | WOS:000817492400001 | - |
dc.relation.journalvolume | 22 | en_US |
dc.relation.journalissue | 12 | en_US |
dc.identifier.eissn | 1424-8220 | - |
item.cerifentitytype | Publications | - |
item.openairetype | journal article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_6501 | - |
item.fulltext | no fulltext | - |
item.grantfulltext | none | - |
item.languageiso639-1 | English | - |
crisitem.author.dept | National Taiwan Ocean University,NTOU | - |
crisitem.author.dept | Department of Electrical Engineering | - |
crisitem.author.dept | College of Electrical Engineering and Computer Science | - |
crisitem.author.parentorg | College of Electrical Engineering and Computer Science | - |
crisitem.author.parentorg | National Taiwan Ocean University,NTOU | - |
顯示於: | 電機工程學系 |
在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。