Title: The Influence of Aggregate Size and Binder Material on the Properties of Pervious Concrete
Authors: Fu, Tun Chi
Wei-Chung Yeih 
Jiang-Jhy Chang 
Huang, Ran
Keywords: POROSITY;ABSORPTION;STRENGTH
Issue Date: 2014
Source: Advances in Materials Science and Engineering
Abstract: 
Specimens were prepared by altering parameters such as aggregate sizes, binder materials, and the amounts of binder used and were subsequently tested by using permeability, porosity, mechanical strength, and soundness tests. The results indicated that the water permeability coefficient and connected porosity decreased as the amount of binder used increased and increased with increasing aggregate size. In the mechanical strength test, the compressive, splitting tensile, and flexural strengths increased as the amount of binder used increased and decreased with the increase of aggregate size. Highly viscous binder enhanced compressive strength, water permeability, and the resistance to sulfate attacks. In the mechanics and sulfate soundness tests, the mix proportion of alkali-activated slag paste used in this study exhibited a superior performance than the Portland cement pervious concrete (the control) did, but the difference in water permeability between the two types of concrete was insignificant. The mix proportions of cement paste containing 20% and 30% silica fume exhibited less mechanical strength than the control did. Moreover, compared with the control, the cement paste containing silica fume demonstrated poor resistance to sulfate attacks, and the difference in the water permeability between such specimen and the control was not noticeable.
URI: http://scholars.ntou.edu.tw/handle/123456789/1435
ISSN: 1687-8434
DOI: 10.1155/2014/963971
Appears in Collections:河海工程學系

Show full item record

WEB OF SCIENCETM
Citations

44
Last Week
0
Last month
checked on Jun 27, 2023

Page view(s)

146
Last Week
0
Last month
0
checked on Jun 30, 2025

Google ScholarTM

Check

Altmetric

Altmetric

Related Items in TAIR


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Explore by
  • Communities & Collections
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Build with DSpace-CRIS - Extension maintained and optimized by Logo 4SCIENCE Feedback