Please use this identifier to cite or link to this item: http://scholars.ntou.edu.tw/handle/123456789/17470
Title: Development of a Continuous Blood Pressure Measurement and Cardiovascular Multi-Indicator Platform for Asian Populations by Using a Back Propagation Neural Network and Dual Photoplethysmography Sensor Signal Acquisition Technology
Authors: Yen, Chih-Ta 
Chang, Sheng-Nan
Cai, Cheng-Yang
Keywords: PULSE TRANSIT-TIME;WAVE;VARIABILITY;OXIMETRY;HEART
Issue Date: 29-May-2021
Publisher: HINDAWI LTD
Journal Volume: 2021
Source: J NANOMATER
Abstract: 
This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography (PPG) sensors and a back propagation neural network (BPNN) that can be used for continuous and rapid measurement of blood pressure and analysis of cardiovascular-related indicators. The proposed platform measured the signal changes in PPG and converted them into physiological indicators, such as pulse transit time (PTT), pulse wave velocity (PWV), perfusion index (PI), heart rate (HR), and pulse wave analysis (PWA); these indicators were then fed into the BPNN to calculate blood pressure. The hardware of the experiment comprised 2 PPG components (i.e., Raspberry Pi 3 Model B and analog-to-digital converter [MCP3008]), which were connected using a serial peripheral interface. The BPNN algorithm converted the stable dual PPG signals acquired from the strictly standardized experimental process into various physiological indicators as input parameters and finally obtained the systolic blood pressure (SBP) and diastolic blood pressure (DBP). To increase the robustness of the BPNN model, this study input data of 100 Asian participants into the training database, including those with and without cardiovascular disease, each with a proportion of approximately 50%. The experimental results revealed that the mean and standard deviation of SBP were 2.23 +/- 2.24 mmHg, with a mean squared error of 3.15 mmHg. The mean and standard deviation of DBP was 3.5 +/- 3.53 mmHg, with a mean squared error of 4.96 mmHg. The proposed real-time blood pressure measurement system exhibited a mean accuracy of 98.22% and 95.58% for SBP and DBP, respectively.
URI: http://scholars.ntou.edu.tw/handle/123456789/17470
ISSN: 1687-4110
DOI: 10.1155/2021/6613817
Appears in Collections:03 GOOD HEALTH AND WELL-BEING
電機工程學系

Show full item record

WEB OF SCIENCETM
Citations

2
Last Week
1
Last month
0
checked on Jun 27, 2023

Page view(s)

146
Last Week
0
Last month
1
checked on Jun 30, 2025

Google ScholarTM

Check

Altmetric

Altmetric

Related Items in TAIR


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Explore by
  • Communities & Collections
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Build with DSpace-CRIS - Extension maintained and optimized by Logo 4SCIENCE Feedback