標題: Development of a Continuous Blood Pressure Measurement and Cardiovascular Multi-Indicator Platform for Asian Populations by Using a Back Propagation Neural Network and Dual Photoplethysmography Sensor Signal Acquisition Technology
作者: Yen, Chih-Ta 
Chang, Sheng-Nan
Cai, Cheng-Yang
關鍵字: PULSE TRANSIT-TIME;WAVE;VARIABILITY;OXIMETRY;HEART
公開日期: 29-五月-2021
出版社: HINDAWI LTD
卷: 2021
來源出版物: J NANOMATER
摘要: 
This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography (PPG) sensors and a back propagation neural network (BPNN) that can be used for continuous and rapid measurement of blood pressure and analysis of cardiovascular-related indicators. The proposed platform measured the signal changes in PPG and converted them into physiological indicators, such as pulse transit time (PTT), pulse wave velocity (PWV), perfusion index (PI), heart rate (HR), and pulse wave analysis (PWA); these indicators were then fed into the BPNN to calculate blood pressure. The hardware of the experiment comprised 2 PPG components (i.e., Raspberry Pi 3 Model B and analog-to-digital converter [MCP3008]), which were connected using a serial peripheral interface. The BPNN algorithm converted the stable dual PPG signals acquired from the strictly standardized experimental process into various physiological indicators as input parameters and finally obtained the systolic blood pressure (SBP) and diastolic blood pressure (DBP). To increase the robustness of the BPNN model, this study input data of 100 Asian participants into the training database, including those with and without cardiovascular disease, each with a proportion of approximately 50%. The experimental results revealed that the mean and standard deviation of SBP were 2.23 +/- 2.24 mmHg, with a mean squared error of 3.15 mmHg. The mean and standard deviation of DBP was 3.5 +/- 3.53 mmHg, with a mean squared error of 4.96 mmHg. The proposed real-time blood pressure measurement system exhibited a mean accuracy of 98.22% and 95.58% for SBP and DBP, respectively.
URI: http://scholars.ntou.edu.tw/handle/123456789/17470
ISSN: 1687-4110
DOI: 10.1155/2021/6613817
顯示於:03 GOOD HEALTH AND WELL-BEING
電機工程學系

顯示文件完整紀錄

WEB OF SCIENCETM
Citations

2
上周
1
上個月
0
checked on 2023/6/27

Page view(s)

146
上周
0
上個月
1
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋