標題: Notch tensile properties of laser-surface-annealed 17-4 PH stainless steel in hydrogen-related environments
作者: L.W. Tsay 
W.C. Lee
R.K .Shiue
J.K. Wu
關鍵字: C. Hydrogen embrittlement;Sulfide stress corrosion cracking;17-4 PH stainless steels;Notch tensile strength
公開日期: 九月-2002
出版社: Corrosion Science
卷: 44
期: 9
起(迄)頁: 2101-2118
摘要: 
Slow displacement rate tensile tests were performed to determine the notched tensile strength (NTS) of 17-4 PH stainless steel with various microstructures in hydrogen-related environments. Solution-annealed (SA), peak-aged (H900), over-aged (H1025), and laser-annealed (LA) specimens were included in the study. Based on the results of NTS in air, the NTS loss in both gaseous hydrogen and H2S-saturated solution was used to access the detrimental effects of hydrogen in 17-4 PH steel subjected to different treatments. Electrochemical permeation tests were also employed to determine the hydrogen permeation characteristics of the 17-4 PH steel plate with various microstructures. The result indicates that all the specimens have low NTS loss in gaseous hydrogen but significantly suffer from sulfide stress corrosion cracking (SCC), especially for the soft SA specimen. It was deduced that high hydrogen diffusivity and less trapped hydrogen atoms in the SA matrix provided rapid transport of massive hydrogen atoms into highly stressed region, and deteriorated the NTS tested in the saturated sulfide solution. On the other hand, H1025 specimen consists of the blocky austenite together with Cu-rich precipitates uniformly distributed in the grain interior; dense and coarse precipitates are also observed along prior austenite grain boundaries. Hydrogen atoms tend to be trapped along grain boundaries, and lead to the formation of intergranular fracture for H1025 specimen tested in the H2S solution. Fine and homogeneously distributed precipitates in the H900 matrix result in uniformly trapping of hydrogen atoms, so it behaves superior properties than other specimens. The decohesion of precipitate/matrix interfaces induces quasi-cleavage fracture of the H900 specimen tested in H2S solution. Finally, the application of laser-annealing treatment on the H900 specimen cannot improve its resistance to sulfide SCC, because the laser-annealed zone is susceptible to hydrogen embrittlement in the H2S solution.
URI: http://scholars.ntou.edu.tw/handle/123456789/19928
DOI: 10.1016/S0010-938X(02)00023-9
顯示於:光電與材料科技學系

顯示文件完整紀錄

Page view(s)

92
上周
0
上個月
3
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋