Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • 首頁
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
  • 分類瀏覽
    • 研究成果檢索
    • 研究人員
    • 單位
    • 計畫
  • 機構典藏
  • SDGs
  • 登入
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 電機資訊學院
  3. 電機工程學系
請用此 Handle URI 來引用此文件: http://scholars.ntou.edu.tw/handle/123456789/20198
標題: Applying a Deep Learning Network in Continuous Physiological Parameter Estimation Based on Photoplethysmography Sensor Signals
作者: Yen, Chih-Ta 
Liao, Jia-Xian
Huang, Yi-Kai
關鍵字: HEART-RATE ESTIMATION;BLOOD-PRESSURE ESTIMATION;PPG SIGNALS;FRAMEWORK
公開日期: 1-一月-2022
出版社: IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
卷: 22
期: 1
起(迄)頁: 385-392
來源出版物: IEEE SENS J
摘要: 
In this paper, we propose a continuous physiological parameter estimation model based on a deep learning network for photoplethysmography (PPG) sensor signals. Signals of 8-s duration were incorporated into the proposed model in this study for frequent estimation of the systolic blood pressure (BP), diastolic BP, heart rate (HR), and mean arterial pressure of the human body; this facilitated early identification and monitoring of physiological conditions and thus reduced the risk of cardiovascular disease. The proposed model was designed using a convolutional neural network (CNN) and long short-term memory (LSTM) network. This model was trained and validated using the large-scale Multiparameter Intelligent Monitoring in Intensive Care database. The CNN was used to extract features from PPG signals automatically. This automatic extraction replaced the conventional manual feature extraction process. Features with time-series were then analyzed using the LSTM network to estimate physiological parameters. Subsequently, ten-fold cross-validation was conducted to reveal the mean absolute errors +/- standard deviations of participants' systolic BP, diastolic BP, HR, and mean arterial pressure to be 2.54 +/- 3.88, 1.59 +/- 2.45, 1.62 +/- 2.55, and 1.59 +/- 2.34 mmHg, respectively. These values meet the standards established by the Association for the Advancement of Medical Instrumentation and the British Hypertension Society. The proposed method facilitates the accurate, continuous monitoring of the BP and HR.
URI: http://scholars.ntou.edu.tw/handle/123456789/20198
ISSN: 1530-437X
DOI: 10.1109/JSEN.2021.3126744
顯示於:03 GOOD HEALTH AND WELL-BEING
電機工程學系

顯示文件完整紀錄

WEB OF SCIENCETM
Citations

4
上周
1
上個月
0
checked on 2023/6/27

Page view(s)

216
上周
0
上個月
2
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋