標題: A Deep Learning-Based Continuous Blood Pressure Measurement by Dual Photoplethysmography Signals
作者: Yen, Chih-Ta 
Chang, Sheng-Nan
Jia-Xian, Liao
Huang, Yi-Kai
關鍵字: PULSE TRANSIT-TIME;HEART
公開日期: 17-二月-2022
出版社: TECH SCIENCE PRESS
卷: 70
期: 2
起(迄)頁: 2937-2952
來源出版物: CMC-COMPUT MATER CON
摘要: 
This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography (PPG) sensors and a deep learning (DL) that can be used for continuous and rapid measurement of blood pressure and analysis of cardiovascular-related indicators. The proposed platform measured the signal changes in PPG and converted them into physiological indicators, such as pulse transit time (PTT), pulse wave velocity (PWV), perfusion index (PI) and heart rate (HR); these indicators were then fed into the DL to calculate blood pressure. The hardware of the experiment comprised 2 PPG components (i.e., Raspberry Pi 3 Model B and analog-to digital converter [MCP3008]), which were connected using a serial peripheral interface. The DL algorithm converted the stable dual PPG signals acquired from the strictly standardized experimental process into various physiological indicators as input parameters and finally obtained the systolic blood pressure (SBP), diastolic blood pressure (DBP) and mean arterial pressure (MAP). To increase the robustness of the DL model, this study input data of 100 Asian participants into the training database, including those with and without cardiovascular disease, each with a proportion of approximately 50%. The experimental results revealed that the mean absolute error and standard deviation of SBP was 0.17 +/- 0.46 mmHg. The mean absolute error and standard deviation of DBP was 0.27 +/- 0.52 mmHg. The mean absolute error and standard deviation of MAP was 0.16 +/- 0.40 mmHg.
URI: http://scholars.ntou.edu.tw/handle/123456789/20203
ISSN: 1546-2218
DOI: 10.32604/cmc.2022.020493
顯示於:03 GOOD HEALTH AND WELL-BEING
電機工程學系

顯示文件完整紀錄

WEB OF SCIENCETM
Citations

1
上周
0
上個月
0
checked on 2023/6/19

Page view(s)

249
上周
4
上個月
2
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋