Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • Home
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
  • Explore by
    • Research Outputs
    • Researchers
    • Organizations
    • Projects
  • Communities & Collections
  • SDGs
  • Sign in
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 電機資訊學院
  3. 電機工程學系
Please use this identifier to cite or link to this item: http://scholars.ntou.edu.tw/handle/123456789/20203
Title: A Deep Learning-Based Continuous Blood Pressure Measurement by Dual Photoplethysmography Signals
Authors: Yen, Chih-Ta 
Chang, Sheng-Nan
Jia-Xian, Liao
Huang, Yi-Kai
Keywords: PULSE TRANSIT-TIME;HEART
Issue Date: 17-Feb-2022
Publisher: TECH SCIENCE PRESS
Journal Volume: 70
Journal Issue: 2
Start page/Pages: 2937-2952
Source: CMC-COMPUT MATER CON
Abstract: 
This study proposed a measurement platform for continuous blood pressure estimation based on dual photoplethysmography (PPG) sensors and a deep learning (DL) that can be used for continuous and rapid measurement of blood pressure and analysis of cardiovascular-related indicators. The proposed platform measured the signal changes in PPG and converted them into physiological indicators, such as pulse transit time (PTT), pulse wave velocity (PWV), perfusion index (PI) and heart rate (HR); these indicators were then fed into the DL to calculate blood pressure. The hardware of the experiment comprised 2 PPG components (i.e., Raspberry Pi 3 Model B and analog-to digital converter [MCP3008]), which were connected using a serial peripheral interface. The DL algorithm converted the stable dual PPG signals acquired from the strictly standardized experimental process into various physiological indicators as input parameters and finally obtained the systolic blood pressure (SBP), diastolic blood pressure (DBP) and mean arterial pressure (MAP). To increase the robustness of the DL model, this study input data of 100 Asian participants into the training database, including those with and without cardiovascular disease, each with a proportion of approximately 50%. The experimental results revealed that the mean absolute error and standard deviation of SBP was 0.17 +/- 0.46 mmHg. The mean absolute error and standard deviation of DBP was 0.27 +/- 0.52 mmHg. The mean absolute error and standard deviation of MAP was 0.16 +/- 0.40 mmHg.
URI: http://scholars.ntou.edu.tw/handle/123456789/20203
ISSN: 1546-2218
DOI: 10.32604/cmc.2022.020493
Appears in Collections:03 GOOD HEALTH AND WELL-BEING
電機工程學系

Show full item record

WEB OF SCIENCETM
Citations

1
Last Week
0
Last month
0
checked on Jun 19, 2023

Page view(s)

249
Last Week
4
Last month
2
checked on Jun 30, 2025

Google ScholarTM

Check

Altmetric

Altmetric

Related Items in TAIR


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Explore by
  • Communities & Collections
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Build with DSpace-CRIS - Extension maintained and optimized by Logo 4SCIENCE Feedback