Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • Home
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
  • Explore by
    • Research Outputs
    • Researchers
    • Organizations
    • Projects
  • Communities & Collections
  • SDGs
  • Sign in
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 電機資訊學院
  3. 電機工程學系
Please use this identifier to cite or link to this item: http://scholars.ntou.edu.tw/handle/123456789/21451
DC FieldValueLanguage
dc.contributor.authorWei-Nen Changen_US
dc.contributor.authorSheng-Huei Leeen_US
dc.contributor.authorYu-Jen Linen_US
dc.contributor.authorJian-Hong Liuen_US
dc.contributor.authorChia-Chi Chuen_US
dc.date.accessioned2022-04-20T01:32:14Z-
dc.date.available2022-04-20T01:32:14Z-
dc.date.issued2020-10-
dc.identifier.isbn978-1-7281-7193-7-
dc.identifier.issn0197-2618-
dc.identifier.urihttp://scholars.ntou.edu.tw/handle/123456789/21451-
dc.description.abstractOne major concern of the industry park (IP) with independent power producers (IPPs) is the protection scheme design, especially when the tie-line with the main grid is suddenly tripped due to some external faults. Under the worst scenarios, the IP may be completely shut down if no proper protection scheme is considered. In order to avoid such possible blackouts, it is necessary to design the relay setting along with appropriate load shedding (LS) schemes and generators' dynamic braking (DB) to maintain the balance between available generation and load, as well as to restore the system frequency and the voltage magnitude. In this paper, the expansion of production in one IP will be considered with deploying additional generators. Extensive numerical simulations under various contingencies are conducted to study dynamical interactions between relay settings and LS/DB mechanisms of this IP. possible Recommendations of revising current protective relay settings and appending an under-frequency relay at the point of common connections (PCC) are comprehensively investigated such that all loads and generation units in this IP still can sustain the unexpected power system disturbances caused by fault contingencies in the main utility system.en_US
dc.language.isoen_USen_US
dc.publisherIEEEen_US
dc.titleEnhancements of Protection Schemes for a Grid-Connected Industry Park with IPPsen_US
dc.typeconference paperen_US
dc.relation.conference2020 IEEE Industry Applications Society Annual Meeting, Detroit, MI, USAen_US
dc.identifier.doi10.1109/IAS44978.2020.9334742-
item.openairetypeconference paper-
item.fulltextno fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_5794-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.languageiso639-1en_US-
crisitem.author.deptNational Taiwan Ocean University,NTOU-
crisitem.author.deptDepartment of Electrical Engineering-
crisitem.author.deptCollege of Electrical Engineering and Computer Science-
crisitem.author.parentorgCollege of Electrical Engineering and Computer Science-
crisitem.author.parentorgNational Taiwan Ocean University,NTOU-
Appears in Collections:電機工程學系
Show simple item record

Page view(s)

124
Last Week
0
Last month
0
checked on Jun 30, 2025

Google ScholarTM

Check

Altmetric

Altmetric

Related Items in TAIR


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Explore by
  • Communities & Collections
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Build with DSpace-CRIS - Extension maintained and optimized by Logo 4SCIENCE Feedback