Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • 首頁
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
  • 分類瀏覽
    • 研究成果檢索
    • 研究人員
    • 單位
    • 計畫
  • 機構典藏
  • SDGs
  • 登入
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 電機資訊學院
  3. 通訊與導航工程學系
請用此 Handle URI 來引用此文件: http://scholars.ntou.edu.tw/handle/123456789/21999
DC 欄位值語言
dc.contributor.authorTsai, Y. H.en_US
dc.contributor.authorYan, Y. J.en_US
dc.contributor.authorLi, Y. S.en_US
dc.contributor.authorChang, C. H.en_US
dc.contributor.authorHaung, C. C.en_US
dc.contributor.authorChen, T. C.en_US
dc.contributor.authorLin, S. G.en_US
dc.contributor.authorOu-Yang, M.en_US
dc.date.accessioned2022-07-01T01:53:03Z-
dc.date.available2022-07-01T01:53:03Z-
dc.date.issued2022-06-01-
dc.identifier.issn0034-6748-
dc.identifier.urihttp://scholars.ntou.edu.tw/handle/123456789/21999-
dc.description.abstractA hyperspectral imaging system (HIS) is a helpful tool that acquires spatial and spectral information from a target. This study developed a coaxial heterogeneous HIS (CHHIS) to collect spectral images with wavelengths ranging from 400 to 1700 nm. In this system, a visible (VIS) spectrometer and a short-wave infrared (SWIR) spectrometer are combined with a coaxial optical path to share the same field of view. This structure reduces the complexity of spatial registration and maintains the scanning duration of two spectrometers as that of a single spectrometer. The spectrometers are also replaceable for extending the detecting spectral range of the system. The calibration methodologies, including spatial correction, spectral calibration, and reflectance calibration, were developed for this system. The signal-to-noise ratio of VIS and SWIR spectrometers in the CHHIS was up to 40 and 60 dB when the exposure time of the VIS and SWIR imaging sensors was 1000 and 10 ms, respectively. When the target distance was at 600 mm, the spatial error of VIS and SWIR images in the scanning direction was less than 1 pixel; these results proved that the system was stable. Published under an exclusive license by AIP Publishing.en_US
dc.language.isoEnglishen_US
dc.publisherAIP Publishingen_US
dc.relation.ispartofREVIEW OF SCIENTIFIC INSTRUMENTSen_US
dc.titleDevelopment and verification of the coaxial heterogeneous hyperspectral imaging systemen_US
dc.typejournal articleen_US
dc.identifier.doi10.1063/5.0088474-
dc.identifier.isiWOS:000808503800002-
dc.relation.journalvolume93en_US
dc.relation.journalissue6en_US
dc.identifier.eissn1089-7623-
item.openairetypejournal article-
item.fulltextno fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.grantfulltextnone-
item.cerifentitytypePublications-
item.languageiso639-1English-
crisitem.author.deptCollege of Electrical Engineering and Computer Science-
crisitem.author.deptDepartment of Communications, Navigation and Control Engineering-
crisitem.author.deptNational Taiwan Ocean University,NTOU-
crisitem.author.parentorgNational Taiwan Ocean University,NTOU-
crisitem.author.parentorgCollege of Electrical Engineering and Computer Science-
顯示於:通訊與導航工程學系
顯示文件簡單紀錄

Page view(s)

170
上周
0
上個月
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋