標題: Design of a Multi-Sensor System for Exploring the Relation between Finger Spasticity and Voluntary Movement in Patients with Stroke
作者: Bor-Shing Lin
I-Jung Lee
Pei-Chi Hsiao
Shu-Yu Yang
Chen-Yu Chen
Si-Huei Lee
Yu-Fang Huang
Mao-Hsu Yen 
Yu Hen Hu
關鍵字: stroke;voluntary movement;spasticity;inertial measurement unit;wearable;modified Ashworth scale
公開日期: 2022
出版社: MPDI
卷: 22
期: 19
來源出版物: Sensors
摘要: 
A novel wearable multi-sensor data glove system is developed to explore the relation between finger spasticity and voluntary movement in patients with stroke. Many stroke patients suffer from finger spasticity, which is detrimental to their manual dexterity. Diagnosing and assessing the degrees of spasticity require neurological testing performed by trained professionals to estimate finger spasticity scores via the modified Ashworth scale (MAS). The proposed system offers an objective, quantitative solution to assess the finger spasticity of patients with stroke and complements the manual neurological test. In this work, the hardware and software components of this system are described. By requiring patients to perform five designated tasks, biomechanical measurements including linear and angular speed, acceleration, and pressure at every finger joint and upper limb are recorded, making up more than 1000 features for each task. We conducted a preliminary clinical test with 14 subjects using this system. Statistical analysis is performed on the acquired measurements to identify a small subset of features that are most likely to discriminate a healthy patient from patients suffering from finger spasticity. This encouraging result validates the feasibility of this proposed system to quantitatively and objectively assess finger spasticity. View Full-Text
URI: http://scholars.ntou.edu.tw/handle/123456789/22475
DOI: 10.3390/s22197212
顯示於:資訊工程學系

顯示文件完整紀錄

Page view(s)

162
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋