Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • 首頁
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
  • 分類瀏覽
    • 研究成果檢索
    • 研究人員
    • 單位
    • 計畫
  • 機構典藏
  • SDGs
  • 登入
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 電機資訊學院
  3. 光電與材料科技學系
請用此 Handle URI 來引用此文件: http://scholars.ntou.edu.tw/handle/123456789/25907
標題: Ultra-sensitive MDM plasmonic sensor for refractive index, CO2 concentration, biomolecule, and temperature detection
作者: Chauhan, Diksha
Dwivedi, Ram Prakash
Sbeah, Zen
Sorathiya, Vishal
Chang, Sheng Hsiung 
關鍵字: Gas sensor;Refractive index sensor;Biomolecules;Temperature sensor;Plasmonics
公開日期: 2025
出版社: ACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD
卷: 205
來源出版物: MICRO AND NANOSTRUCTURES
摘要: 
This paper presents a metal-dielectric-metal configuration based plasmonic refractive index sensor for applications like gas, biomolecule and temperature detection. The device consists of a rectangular ring resonator coupled to a straight waveguide. Initially the device has shown its application as a simple refractive index sensor, where the device can sense refractive indexes in the range from 1.0 to 1.1 with the maximum sensitivity of 2400 nm/refractive index unit (RIU). This device is used as a gas sensor for detecting the concentration of CO2, for that Polyhexamethylene biguanide (PHMB) is added to the rectangular ring resonator and then by changing the refractive index of PHMB layer via adsorbing CO2 molecules, the change in the concentration of CO2 gas is detected. A sensitivity of 46.51 p.m./parts per million (ppm) is theoretically obtained for the different concentrations of CO2 from 0 ppm to 524 ppm. Then the device is simulated to sense various biomolecules, where detection of colorless biomaterial, anemia, creatinine and prostate cancer is performed. In the detection of anemia, the sensitivity of 3333nm/RIU is predicted. Additionally, for colorless biomolecules, static sensitivity of 2000 nm/RIU, for creatinine maximum sensitivity of 1500nm/RIU and maximum sensitivity of 2259.8 nm/RIU is predicted for prostate. Besides, this device is also used as a temperature sensor by using the Polydimethylsiloxane (PDMS) as the dielectric material, whose refractive index changes from 1.3861 to 1.4041 for different temperatures ranging between 80 degrees C and 20 degrees C. For the temperature detection, the sensitivity of 2 nm/degrees C is predicted.
URI: http://scholars.ntou.edu.tw/handle/123456789/25907
DOI: 10.1016/j.micrna.2025.208211
顯示於:光電與材料科技學系

顯示文件完整紀錄

Page view(s)

48
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋