標題: Analysis and improvement on frequency sensitivity of series photodetector frequency circuit system and its application for HEX fluorescence measurement
作者: Hsu, Y. M.
Chung-Cheng Chang 
關鍵字: Photodetectors;Luminescence;Fluorescence spectroscopy;Sensors;Capacitance;Light sources;Oscillators;Phototransistors;Signal detection;Quartz
公開日期: 四月-2011
卷: 50
期: 4
來源出版物: Optical Engineering
摘要: 
This study reported the improvement of frequency sensitivity of series photodetector frequency circuit system for fluorescence detection. The 48 MHz series photodetector frequency circuit system matched with polydimethyl siloxane (PDMS) focusing lens was applied to the detection of emissive fluorescence intensity. MEMS technology processes were used to fabricate PDMS focusing lens, the mixing amount of PDMS and the curing temperature were adjusted, and self-improved mold-transfer technology was used to make a 3D planar lens of diameter of 3 to 10 mm. While the series photodetector frequency circuit system matched with PDMS focusing lens of diameter 10 mm was used for fluorescence detection, the relative fluorescence intensity was enhanced by approximately two times, which indicated that the frequency sensitivity of the 48 MHz sensor system was improved. Besides, the bias of the photodetector was also adjusted to improve the frequency sensitivity. According to the optimal conditions of PDMS focusing lens and bias of a photodetector, the detection limit of HEX fluorescence dye concentration 3.3 pmol/L can be measured. The results of the fluorescence experiment also demonstrated that the frequency shift of the 48 MHz sensor system was linearly related to the logarithm of fluorescence dye concentration from 333.3 nmol/L to 3.3 pmol/L.
URI: http://scholars.ntou.edu.tw/handle/123456789/7589
ISSN: 0091-3286
DOI: ://WOS:000290028900019
://WOS:000290028900019
://WOS:000290028900019
://WOS:000290028900019
://WOS:000290028900019
10.1117/1.3567067
://WOS:000290028900019
://WOS:000290028900019
顯示於:電機工程學系

顯示文件完整紀錄

Page view(s)

154
上周
1
上個月
0
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋