Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • 首頁
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
  • 分類瀏覽
    • 研究成果檢索
    • 研究人員
    • 單位
    • 計畫
  • 機構典藏
  • SDGs
  • 登入
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 生命科學院
  3. 生命科學暨生物科技學系
請用此 Handle URI 來引用此文件: http://scholars.ntou.edu.tw/handle/123456789/17496
標題: Engineering Layered Nanostructures of Two-Dimensional Transition Metal Dichalcogenides with CeO2 for Nano-Level Detection of Promethazine Hydrochloride
作者: Selvi, Subash Vetri
Nataraj, Nandini
Chen, Tse-Wei
Chen, Shen Ming
Wu, Wei-Ling
Tseng, Tien-Wen
Huang, Chih-Ching 
關鍵字: MoS2 Nanosheets;Cerium oxide;Phenothiazine derivative;Biological samples
公開日期: 1-七月-2021
出版社: ELECTROCHEMICAL SOC INC
卷: 168
期: 7
來源出版物: JOURNAL OF THE ELECTROCHEMICAL SOCIETY
摘要: 
Transition metal dichalcogenides (TMC) are utilized in diverse applications due to their 2D structure and effective tendencies. Molybdenum disulfide (MoS2) based TMC is emphasized for its lamellar structure with enormous edges which afford faster transfer of electrons for detecting molecules. To promote the action of conductance of MoS2, metal oxide can be employed and cerium oxide (CeO2) with abundant distinguishable properties was embedded with MoS2. The nanocomposite MoS2/CeO2 was characterized for structural and functional analysis by X-ray diffraction, Raman, and Fourier infra-red spectroscopy, resulting in the pure presence of MoS2/CeO2 without additional constituent peaks. CeO2 nanorods embedded over MoS2 nanosheets were identified with field-emission scanning electron microscopy and their elemental presence identified with X-ray photoelectron spectroscopy and EDAX analysis. When fabricated over glassy carbon electrode (GCE) MoS2/CeO2 showed superior conductivity facilitated by the higher active sites provided by MoS2/CeO2 toward promethazine hydrochloride (PZC) oxidation. The resistance of the designed MoS2/CeO2 electrode, similar to 61 omega, is attributed to the synergetic conducting behavior. The stability of the electrode was consistent with the similar current response over 20 days. When used for real-time detection in biological samples, the MoS2/CeO2/GCE established excellent response and a detection limit at 3 nM for the linear range from 0.009-695 mu M was obtained.
URI: http://scholars.ntou.edu.tw/handle/123456789/17496
ISSN: 0013-4651
DOI: 10.1149/1945-7111/ac0ec7
顯示於:生命科學暨生物科技學系

顯示文件完整紀錄

WEB OF SCIENCETM
Citations

1
上周
0
上個月
0
checked on 2023/6/27

Page view(s)

126
上周
0
上個月
0
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋