Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • 首頁
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
  • 分類瀏覽
    • 研究成果檢索
    • 研究人員
    • 單位
    • 計畫
  • 機構典藏
  • SDGs
  • 登入
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 生命科學院
  3. 生命科學暨生物科技學系
請用此 Handle URI 來引用此文件: http://scholars.ntou.edu.tw/handle/123456789/17819
DC 欄位值語言
dc.contributor.authorLin, Wei-Janen_US
dc.contributor.authorLin, Yu-Syuanen_US
dc.contributor.authorChang, Huan-Tsungen_US
dc.contributor.authorUnnikrishnan, Bineshen_US
dc.contributor.authorHuang, Chih-Chingen_US
dc.date.accessioned2021-10-13T05:51:02Z-
dc.date.available2021-10-13T05:51:02Z-
dc.date.issued2021-12-15-
dc.identifier.issn0956-5663-
dc.identifier.urihttp://scholars.ntou.edu.tw/handle/123456789/17819-
dc.description.abstractHighly electrocatalytic cuprous halide/copper oxide nanoparticles (CuX@CunO NPs; X = Cl, Br or I; n = 1 or 2) have been fabricated on copper foils for sensitive detection of glucose. Formation of CuX@CunO NPs involves two steps- in situ electrochemical deposition of CuX on the foil and then conversion of CuX to CunO. The deposited CuX converts to CunO, leading to the generation of abundant oxygen vacancies in the CuO lattice, enhancing the number of catalytically active sites, and improving the charge transfer efficiency. Among the asprepared electrodes, CuBr@CuO NP ones provide the highest electrocatalytic activity toward the oxidation of glucose. The electrode provides electrocatalytic activity toward the oxidation of glucose at a low overpotential of 0.25 V (vs. SCE), which is lower than that (0.40 V) of unmodified copper electrodes. The generated anodic current is proportional to glucose concentration in an alkaline medium, with a good linear range from 5.0 mu M to 3.51 mM (R2 = 0.995). Its reliability has been validated by detecting the glucose concentration in saliva samples at different time intervals after a meal. The results are in good correlation with the blood glucose level determined by using a commercial blood glucose meter. Our CuBr@CuO NP electrode possesses great potential for monitoring salivary glucose to achieve the purpose of noninvasive glucose monitoring for patients with diabetes in the future.en_US
dc.language.isoen_USen_US
dc.publisherELSEVIER ADVANCED TECHNOLOGYen_US
dc.relation.ispartofBIOSENS BIOELECTRONen_US
dc.subjectCANDIDAL CARRIAGEen_US
dc.subjectELECTRODEPOSITIONen_US
dc.subjectPHOTOCATALYSTen_US
dc.subjectREDUCTIONen_US
dc.subjectBIOSENSORen_US
dc.subjectOXIDATIONen_US
dc.subjectCATALYSTSen_US
dc.subjectINSIGHTen_US
dc.subjectSENSORen_US
dc.titleElectrocatalytic CuBr@CuO nanoparticles based salivary glucose probesen_US
dc.typejournal articleen_US
dc.identifier.doi10.1016/j.bios.2021.113610-
dc.identifier.isiWOS:000697701100007-
dc.relation.journalvolume194en_US
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.cerifentitytypePublications-
item.languageiso639-1en_US-
item.fulltextno fulltext-
item.grantfulltextnone-
item.openairetypejournal article-
crisitem.author.deptCollege of Life Sciences-
crisitem.author.deptDepartment of Bioscience and Biotechnology-
crisitem.author.deptNational Taiwan Ocean University,NTOU-
crisitem.author.deptCenter of Excellence for the Oceans-
crisitem.author.orcid0000-0002-0363-1129-
crisitem.author.parentorgNational Taiwan Ocean University,NTOU-
crisitem.author.parentorgCollege of Life Sciences-
crisitem.author.parentorgNational Taiwan Ocean University,NTOU-
顯示於:生命科學暨生物科技學系
03 GOOD HEALTH AND WELL-BEING
顯示文件簡單紀錄

WEB OF SCIENCETM
Citations

10
上周
0
上個月
0
checked on 2023/6/27

Page view(s)

234
上周
0
上個月
4
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋