標題: Hybrid Graphene-Based Photonic-Plasmonic Biochemical Sensor with a Photonic and Acoustic Cavity Structure
作者: Yang, Chan-Shan
Cheng, Yi-Sheng
Hsu, Young-Chou
Chung, Yi-Cheng
Hung, Jing-Ting
Liu, Chien-Hao
Hsu, Jin-Chen
Cheng-Ying Chen 
Yang, Chii-Rong
Li, Yu-Tai
Huang, Nan-Nong 
Lin, Tzy-Rong 
關鍵字: graphene;plasmon;photonic cavity;phoxonic crystal;biochemical sensor
公開日期: 1-十月-2021
出版社: MDPI
卷: 11
期: 10
來源出版物: CRYSTALS
摘要: 
In this study, we propose a biochemical sensor that features a photonic cavity integrated with graphene. The tunable hybrid plasmonic-photonic sensor can detect the molecular fingerprints of biochemicals with a small sample volume. The stacking sequence of the device is "ITO grating/graphene/TiO2/Au/Si substrate ", which composes a photonic band gap structure. A defect is created within the ITO gratings to form a resonant cavity. The plasmonic-photonic energy can be confined in the cavity to enhance the interaction between light and the analyte deposited in the cavity. The finite element simulation results indicated that the current sensor exhibits very high values in resonance shift and sensitivity. Moreover, the resonance spectrum with a broad resonance linewidth can identify the molecular vibration bands, which was exemplified by the fingerprint detections of protein and the chemical compound CBP. The sensor possesses an electrical tunability by including a graphene layer, which allowed us to tune the effective refractive index of the cavity to increase the sensor's sensing performance. In addition, our device admits a phononic bandgap as well, which was exploited to sense the mechanical properties of two particular dried proteins based on the simplified elastic material model instead of using the more realistic viscoelastic model. The dual examinations of the optical and mechanical properties of analytes from a phoxonic sensor can improve the selectivity in analyte detections.

URI: http://scholars.ntou.edu.tw/handle/123456789/19109
DOI: 10.3390/cryst11101175
顯示於:機械與機電工程學系

顯示文件完整紀錄

WEB OF SCIENCETM
Citations

1
上周
0
上個月
0
checked on 2023/6/27

Page view(s)

167
上周
0
上個月
0
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋