標題: A study on corrosion and corrosion-wear behavior of Fe-based amorphous alloy coating prepared by high velocity oxygen fuel method
作者: Lee, Chun-Ying
Lin, Tzu-Jing
Sheu, Hung-Hua
Lee, Hung-Bin 
關鍵字: HVOF;Fe-based amorphous alloy;Corrosion-wear;Corrosion
公開日期: 1-十一月-2021
出版社: ELSEVIER
卷: 15
起(迄)頁: 4880-4895
來源出版物: JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T
摘要: 
In this study, the corrosion-wear behavior of a Fe-based amorphous alloy coating was analyzed using a pin-on-ring corrosion abrasion system. The Fe-based amorphous alloy coating was prepared by the high velocity oxygen fuel (HVOF) method. The purpose of this article is to study the corrosion-wear behavior of this Fe-based amorphous alloy coating in sea water. The dynamic potential polarization curve and friction coefficient measurement were used to explore the influence of different polarization potentials on the corrosion-wear of the Fe-based amorphous alloy coating. The corrosion behavior of the coating was also analyzed using SEM, TEM and XPS. The experimental results show that under low polarization potential, after the iron oxide is dissolved, the chromium element in the Fe-based amorphous alloy coating will form chromium trioxide to produce a passivation protective layer. However, when the polarization potential is increased, the chromium trioxide will begin to dissolve. Subsequently, the molybdate formed by the passivation layer of molybdenum dioxide and molybdenum trioxide will provide more effective corrosion resistance of this Fe-based amorphous alloy coating. In terms of corrosion-wear behavior, owing to high hardness of the Fe-based amorphous alloy, the wear rate under low polarization potential is very small. When the polarization potential increases, a softer passivation layer will be formed on the surface of the coating, which will cause the wear rate to increase. As the polarization potential is +200 mV(SC)(E), the wear mechanism of the coating is mainly a plowing type. While at high polarization potential (+600 mV(SCE)), it changes to a corrosive wear type. (C) 2021 The Author(s). Published by Elsevier B.V.
URI: http://scholars.ntou.edu.tw/handle/123456789/19552
ISSN: 2238-7854
DOI: 10.1016/j.jmrt.2021.10.103
顯示於:光電與材料科技學系

顯示文件完整紀錄

WEB OF SCIENCETM
Citations

18
上周
1
上個月
checked on 2023/6/27

Page view(s)

143
上周
0
上個月
0
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋