標題: Fatigue crack growth of AISI 304 stainless steel welds in air and hydrogen
作者: L.W. Tsay 
Y.C. Liu
M.C. Young
D.-Y. Lin
關鍵字: Fatigue crack growth;AISI 304 stainless steel;Plasma weld;Stress-relieved treatment;Strain-induced martensite;Quasi-cleavage fracture
公開日期: 六月-2004
卷: 374
期: 1-2
起(迄)頁: 204-210
摘要: 
Fatigue crack growth behavior of AISI 304 stainless steel plate and its plasma weld was evaluated in laboratory air and gaseous hydrogen. Observed variation in crack growth characteristics are explained based on the martensitic transformations near the crack tip due to mechanical loading and environmental action. The microstructures of fusion zone consisted of lacy ferrites in the columnar grain and subgrain boundaries within the austenite matrix, versus equiaxial austenite grains with some twins inside the parent metal. The threshold ΔK of the as-welded (AW) specimen required to initiate crack growth was clearly higher than that of the other specimens, regardless of testing environments. The considerable retardation of crack growth vanished for welds subjected to stress-relief treatment. In addition, all specimens tested in gaseous hydrogen exhibited enhanced crack growth.

The fatigue-fractured surface of welds was found to be very rough suggesting a zig-zag crack path, unlike the straight path in the base metal. The lack of twin boundary failures in addition to the irregular solidified microstructure could be the causes for the improved resistance to fatigue crack growth in case of the stress-relieved weld. Moreover, the thin martensite layer formed on the cracked surface was correlated with the hydrogen-enhanced crack growth, resulting in inducing extensive quasi-cleavage (QC) fracture for the specimens tested in hydrogen.
URI: http://scholars.ntou.edu.tw/handle/123456789/19926
DOI: 10.1016/j.msea.2004.02.018
顯示於:光電與材料科技學系

顯示文件完整紀錄

Page view(s)

90
上周
0
上個月
3
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋