標題: Geological reference standards (JLK-1,JSD-1, JSD-2, JSD-3,JMS-1, JMS-2) measured by Itrax-XRF core scanner in different exposure times, supplement to: Huang, Jyh-Jaan; Löwemark, Ludvig; Chang, Queenie; Lin, Tzu-Yu; Chen, Huei-Fen; Song, Sheng-Rong; Wei, Kuo-Yen (2016): Choosing optimal exposure times for XRF core-scanning: Suggestions based on the analysis of geological reference materials. Geochemistry, Geophysics, Geosystems, 17(4), 1558-1566
作者: Jyh-Jaan Steven Huang
Ludvig Löwemark
ueenie Chang
Tzu-Yu Lin
Huei-Fen Chen 
Sheng-Rong Song
Kuo-Yen Wei
公開日期: 一月-2016
卷: 17
期: 4
起(迄)頁: 1519-1566
來源出版物: Geochemistry, Geophysics, Geosystems
摘要: 
X-ray fluorescence (XRF) core-scanning is a fast and nondestructive technique to assess elemental variations of unprocessed sediments. However, although the exposure time of XRF-scanning directly affects the scanning counts and total measurement time, only a few studies have considered the influence of exposure time during the scan. How to select an optimal exposure time to achieve reliable results and reduce the total measurement time is an important issue. To address this question, six geological reference materials from the Geological Survey of Japan (JLK-1, JMS-1, JMS-2, JSD-1, JSD-2, and JSD-3) were scanned by the Itrax-XRF core scanner using the Mo- and the Cr-tube with different exposure times to allow a comparison of scanning counts with absolute concentrations. The regression lines and correlation coefficients of elements that are generally used in paleoenvironmental studies were examined for the different exposure times and X-ray tubes. The results show that for those elements with relatively high concentrations or high detectability, the correlation coefficients are higher than 0.90 for all exposure times. In contrast, for the low detectability or low concentration elements, the correlation coefficients are relatively low, and improve little with increased exposure time. Therefore, we suggest that the influence of different exposure times is insignificant for the accuracy of the measurements. Thus, caution must be taken when interpreting the results of elements with low detectability, even when the exposure times are long and scanning counts are reasonably high.
URI: http://scholars.ntou.edu.tw/handle/123456789/19982
DOI: 10.1594/PANGAEA.858766
顯示於:地球科學研究所

顯示文件完整紀錄

Page view(s)

124
上周
2
上個月
0
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋