Title: Applications of System Integrity Protection Scheme and Multi-Phase Reclosing of Transmission Lines for Stability Enhancement in Taiwan Power System
Authors: Sheng-Huei Lee
Wei-Chang Sung
Jian-Hong Liu 
Ying-Yi Hong
Young-Huei Hong
Chiao-Hung Wang
Chia-Chi Chu
Keywords: Circuit faults;Power system stability;Power transmission lines;Transient analysis;Power generation;Reliability;Generators;Generation rejection schemes;multiphase autoreclosing;reliability assessment;special integration protection scheme;transient stability enhancement
Issue Date: Oct-2021
Publisher: IEEE
Journal Volume: 57
Journal Issue: 5
Start page/Pages: 4548 - 4557
Source: Transactions on Industry Applications
Abstract: 
Due to generation increase and load growing in recent years, Taiwan power system has faced with some transient instability problems. To tackle out this challenging task, two advanced techniques, including system integration protection scheme (SIPS) and automatic reclosing of transmission lines, are considered in Taiwan power system recently for transient stability enhancement. In facing three-phase faults, the generator rejection scheme (GRS) in SIPS is recommended for quickly maintaining the power balance. The reliability-based GRS with redundant voting mechanisms is conducted to reduce the risk of inappropriate GRS. Detailed settings of the arming threshold of the GRS are investigated by minimizing the risk contributed by unsuccessful operations and accidental operations. For other temporary nonsevere N-2 contingencies, the multiphase automatic reclosing scheme is considered to restore the system in the timing manner. Impacts of unbalanced fault current with respect to the withstanding capability of the generator are also studied. Simulation studies are conducted to validate the effectiveness and applicability of the proposed solution.
URI: http://scholars.ntou.edu.tw/handle/123456789/21464
ISSN: 0093-9994
DOI: 10.1109/TIA.2021.3088088
Appears in Collections:電機工程學系

Show full item record

Page view(s)

122
Last Week
0
Last month
0
checked on Jun 30, 2025

Google ScholarTM

Check

Altmetric

Altmetric

Related Items in TAIR


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Explore by
  • Communities & Collections
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Build with DSpace-CRIS - Extension maintained and optimized by Logo 4SCIENCE Feedback