Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • 首頁
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
  • 分類瀏覽
    • 研究成果檢索
    • 研究人員
    • 單位
    • 計畫
  • 機構典藏
  • SDGs
  • 登入
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 工學院
  3. 機械與機電工程學系
請用此 Handle URI 來引用此文件: http://scholars.ntou.edu.tw/handle/123456789/26201
DC 欄位值語言
dc.contributor.authorChuang, Shang-Chingen_US
dc.contributor.authorKuo, Cheng-Hsienen_US
dc.contributor.authorWang, Yao-Mingen_US
dc.contributor.authorHsu, Ning-Yihen_US
dc.contributor.authorLin, Han-Jouen_US
dc.contributor.authorKuo, Jen-Yuanen_US
dc.contributor.authorChou, Chau-Changen_US
dc.date.accessioned2026-03-12T03:20:27Z-
dc.date.available2026-03-12T03:20:27Z-
dc.date.issued2025/12/4-
dc.identifier.urihttp://scholars.ntou.edu.tw/handle/123456789/26201-
dc.description.abstractAccurate and real-time state of charge (SOC) monitoring is critical for the safe, efficient, and stable long-term operation of vanadium redox flow batteries (VRFBs). Traditional monitoring methods are susceptible to errors arising from side reactions, cumulative drift, and electrolyte imbalance. This study develops a non-invasive optical sensor module for the negative electrolyte (anolyte), utilizing the favorable spectral properties of V(II)/V(III) ions at 850 nm for real-time SOC tracking. A fifth-order polynomial model was employed for calibration, successfully managing the non-linear optical response of highly concentrated electrolytes and achieving exceptional accuracy (adjusted R-2 > 0.9999). The optical sensor reliably tracked capacity degradation over 50 galvanostatic cycles, yielding a degradation curve that showed a high correlation with the conventional coulomb counting method, thus confirming its feasibility for assessing battery's state of health. Contrary to initial expectations, operating at higher current densities resulted in a lower capacity degradation rate (CDR). This phenomenon is primarily attributed to the time-dependent nature of parasitic side reactions. Higher current densities reduce the cycle duration, thereby minimizing the temporal exposure of active species to degradation mechanisms and mitigating cumulative ion imbalance. This mechanism was corroborated by physicochemical analysis via UV-Vis spectroscopy, which revealed a strong correlation between the severity of spectral deviation and the CDR ranking. This non-invasive optical technology offers a low-cost and effective solution for precise VRFB management and preventative maintenance.en_US
dc.language.isoEnglishen_US
dc.publisherMDPIen_US
dc.relation.ispartofENERGIESen_US
dc.subjectvanadium redox flow battery (VRFB)en_US
dc.subjectstate of charge (SOC)en_US
dc.subjectoptical monitoringen_US
dc.subjectcapacity fadingen_US
dc.subjection imbalanceen_US
dc.titleA Non-Invasive Optical Sensor for Real-Time State of Charge and Capacity Fading Tracking in Vanadium Redox Flow Batteriesen_US
dc.typejournal articleen_US
dc.identifier.doi10.3390/en18236366-
dc.identifier.isiWOS:001635451500001-
dc.relation.journalvolume18en_US
dc.relation.journalissue23en_US
dc.relation.pages20en_US
dc.identifier.eissn1996-1073-
item.cerifentitytypePublications-
item.fulltextno fulltext-
item.grantfulltextnone-
item.openairecristypehttp://purl.org/coar/resource_type/c_6501-
item.languageiso639-1English-
item.openairetypejournal article-
crisitem.author.deptCollege of Engineering-
crisitem.author.deptDepartment of Mechanical and Mechatronic Engineering-
crisitem.author.deptNational Taiwan Ocean University,NTOU-
crisitem.author.orcid0000-0003-1038-0628-
crisitem.author.parentorgNational Taiwan Ocean University,NTOU-
crisitem.author.parentorgCollege of Engineering-
顯示於:機械與機電工程學系
顯示文件簡單紀錄

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋