Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • Home
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
  • Explore by
    • Research Outputs
    • Researchers
    • Organizations
    • Projects
  • Communities & Collections
  • SDGs
  • Sign in
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 電機資訊學院
  3. 電機工程學系
Please use this identifier to cite or link to this item: http://scholars.ntou.edu.tw/handle/123456789/7576
Title: A study on the biological detection chip through the use of PDMS lens for the reinforcement of fluorescence receiving signal
Authors: Chung-Cheng Chang 
Hsu, Y. M.
Chen, T. C.
Ho, C. C.
Chen, C. T.
Chen, P. T.
Keywords: Microfluidic chip;PDMS lens;Laser;Fluorescence
Issue Date: Apr-2014
Publisher: ScienceDirect
Journal Volume: 125
Journal Issue: 7
Start page/Pages: 1846-1852
Source: Optik
Abstract: 
In this study, MEMS process technology is adopted to produce microfluidic chip and PDMS lens. SU-8 thick film photo resist is coated onto silicon wafer surface in two times of spin coating, then through lithography and mold transfer technology, PDMS chip of minimal line width 100 μm and thickness 200 μm is printed. In fluorescence detection aspect, we use objective lens to couple laser optical source to optical fiber, and then have it incident to excite fluorescence sample, the excited fluorescence then passes through filter and detected by optical detector of experiment group and spectrophotometer of reference group. From the experiment result, the Hex fluorescence detection limit of the system is verified to be 1 pmol/5 μl. In addition, we have integrated PDMS lens into microfluidic chip to make generalized detection experiment, it was found that the signal measured by optical embedded type is higher than that of non-embedded type. Meanwhile, the microfluidic chip with double concave lens (135°) and10 mm PDMS focusing lens can be utilized to obtain optimal fluorescence receiving effect. The fluorescence intensity is raised by 2–3 times, and the measurement limit is lowered to 100 fmol/5 μl.
URI: http://scholars.ntou.edu.tw/handle/123456789/7576
ISSN: 0030-4026
DOI: ://WOS:000331345000009
://WOS:000331345000009
10.1016/j.ijleo.2013.09.068
://WOS:000331345000009
://WOS:000331345000009
Appears in Collections:電機工程學系

Show full item record

Page view(s)

137
Last Week
0
Last month
0
checked on Jun 30, 2025

Google ScholarTM

Check

Altmetric

Altmetric

Related Items in TAIR


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Explore by
  • Communities & Collections
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Build with DSpace-CRIS - Extension maintained and optimized by Logo 4SCIENCE Feedback