Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • 首頁
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
  • 分類瀏覽
    • 研究成果檢索
    • 研究人員
    • 單位
    • 計畫
  • 機構典藏
  • SDGs
  • 登入
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 電機資訊學院
  3. 電機工程學系
請用此 Handle URI 來引用此文件: http://scholars.ntou.edu.tw/handle/123456789/7590
Title: Improvement of frequency sensitivity of series photodetector frequency circuit system and its application for Cy5 fluorescence detection
Authors: Hsu, Y. M.
Chung-Cheng Chang 
Keywords: Series photodetector frequency circuit system;Photodetector;DNA probe;Fluorescence dye concentration;Cy5
Issue Date: Oct-2011
Publisher: ELSEVIER
Journal Volume: 122
Journal Issue: 19
Start page/Pages: 1747-1752
Source: Optik
Abstract: 
This study elucidated the frequency characteristics of series photodetector frequency circuit system for detection of DNA probe ET996 marked with fluorescence dye Cy5. We developed 48 MHz series photodetector frequency circuit system with good sensitivity for fluorescence detection. In accordance with the theory of series photodetector frequency circuit system, the frequency sensitivity can be improved by adjusting circuit parameters such as A (tan θ), Cq, C0, and Cp. In this research of A adjustment, the capacitance parameter Cm of 48 MHz series photodetector frequency circuit system was adjusted to improve the frequency sensitivity for detection of fluorescence dye concentration; moreover, the bias of photodetector was also adjusted to improve the frequency sensitivity. In the optimal conditions of capacitance match and photodetector bias, the detection limit of ET996-Cy5 fluorescence dye concentration 2 pmol/L can be measured by 48 MHz sensor system. The results of fluorescence experiment also demonstrated that the frequency shift of 48 MHz sensor system was linearly related to the logarithm of fluorescence dye concentration from 200 nmol/L to 2 pmol/L. The frequency method can be applied simply and the detection limit of ET996-Cy5 fluorescence dye concentration was lower than the conventional fluorescence technique by 2 orders.
URI: http://scholars.ntou.edu.tw/handle/123456789/7590
ISSN: 0030-4026
DOI: ://WOS:000295433300013
://WOS:000295433300013
://WOS:000295433300013
://WOS:000295433300013
://WOS:000295433300013
://WOS:000295433300013
10.1016/j.ijleo.2010.10.036
://WOS:000295433300013
://WOS:000295433300013
Appears in Collections:電機工程學系

Show full item record

Page view(s)

129
Last Week
1
Last month
0
checked on Jun 30, 2025

Google ScholarTM

Check

Altmetric

Altmetric

Related Items in TAIR


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋