Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • 首頁
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
  • 分類瀏覽
    • 研究成果檢索
    • 研究人員
    • 單位
    • 計畫
  • 機構典藏
  • SDGs
  • 登入
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 生命科學院
  3. 生命科學暨生物科技學系
請用此 Handle URI 來引用此文件: http://scholars.ntou.edu.tw/handle/123456789/21983
標題: Ratiometric Fluorescence Probe of Vesicle-like Carbon Dots and Gold Clusters for Quantitation of Cholesterol
作者: Hu, Shun-Ruei
Yang, Chang-Ruei
Huang, Yu-Fen
Huang, Chih-Ching 
Chen, Yen-Ling
Chang, Huan-Tsung
關鍵字: vesicle-like carbon dots;gold nanoclusters;ratiometric fluorescence probe;cholesterol
公開日期: 1-五月-2022
出版社: MDPI
卷: 10
期: 5
來源出版物: CHEMOSENSORS
摘要: 
We report a facile method for the preparation of vesicle-like carbon dots (VCDs) via dry-heating of surfactant solutions. Like most reported CDs, the VCDs possess interesting fluorescence properties. Entrapment of enzymes and gold nanoclusters (AuNCs) inside the VCDs allows for the development of fluorescent probes for the quantitation of various substrates, with the advantages of high sensitivity and selectivity. The AuNCs act as a probe, and the VCDs as an internal standard confine the AuNCs, enzyme, and analyte to provide high local concentrations to enhance the assay sensitivity. In this study, we employed cholesterol oxidase (ChOX) as a model enzyme for the quantitation of cholesterol. The as-formed hydrogen peroxide through the enzyme reaction inside the VCDs causes fluorescence quenching of AuNCs (excitation/emission wavelengths of 320/670 nm), but not that of the VCDs (excitation/emission wavelengths of 320/400 nm). To improve the sensitivity and linearity, the fluorescence ratios of AuNCs/VCDs are plotted against analyte concentration. The present ratiometric fluorescent method allows for the detection of hydrogen peroxide over the concentration range of 1-100 mu M, with a detection limit of 0.673 mu M, and cholesterol concentrations ranging from 5 to 100 mu M, with a detection limit of 2.8 mu M. The practicality of this fluorescent method has been further validated by evaluating cholesterol levels in human serum samples with sufficient accuracy and recovery, revealing its great prospective in diagnosis and biomedical applications.
URI: http://scholars.ntou.edu.tw/handle/123456789/21983
DOI: 10.3390/chemosensors10050160
顯示於:生命科學暨生物科技學系

顯示文件完整紀錄

WEB OF SCIENCETM
Citations

1
上周
0
上個月
checked on 2023/5/7

Page view(s)

199
上周
0
上個月
checked on 2025/6/30

Google ScholarTM

檢查

Altmetric

Altmetric

TAIR相關文章


在 IR 系統中的文件,除了特別指名其著作權條款之外,均受到著作權保護,並且保留所有的權利。

瀏覽
  • 機構典藏
  • 研究成果檢索
  • 研究人員
  • 單位
  • 計畫
DSpace-CRIS Software Copyright © 2002-  Duraspace   4science - Extension maintained and optimized by NTU Library Logo 4SCIENCE 回饋