Please use this identifier to cite or link to this item: http://scholars.ntou.edu.tw/handle/123456789/22048
Title: Non-Invasive Blood Glucose Estimation System Based on a Neural Network with Dual-Wavelength Photoplethysmography and Bioelectrical Impedance Measuring
Authors: Yen, Chih-Ta 
Chen, Un-Hung
Wang, Guo-Chang
Chen, Zong-Xian
Keywords: blood glucose estimation;photoplethysmography (PPG);bioelectrical impedance;principal component analysis (PCA);back-propagation neural network (BPNN)
Issue Date: 1-Jun-2022
Publisher: MDPI
Journal Volume: 22
Journal Issue: 12
Source: SENSORS
Abstract: 
This study proposed a noninvasive blood glucose estimation system based on dual-wavelength photoplethysmography (PPG) and bioelectrical impedance measuring technology that can avoid the discomfort created by conventional invasive blood glucose measurement methods while accurately estimating blood glucose. The measured PPG signals are converted into mean, variance, skewness, kurtosis, standard deviation, and information entropy. The data obtained by bioelectrical impedance measuring consist of the real part, imaginary part, phase, and amplitude size of 11 types of frequencies, which are converted into features through principal component analyses. After combining the input of seven physiological features, the blood glucose value is finally obtained as the input of the back-propagation neural network (BPNN). To confirm the robustness of the system operation, this study collected data from 40 volunteers and established a database. From the experimental results, the system has a mean squared error of 40.736, a root mean squared error of 6.3824, a mean absolute error of 5.0896, a mean absolute relative difference of 4.4321%, and a coefficient of determination (R Squared, R-2) of 0.997, all of which fall within the clinically accurate region A in the Clarke error grid analyses.
URI: http://scholars.ntou.edu.tw/handle/123456789/22048
DOI: 10.3390/s22124452
Appears in Collections:電機工程學系

Show full item record

WEB OF SCIENCETM
Citations

1
Last Week
1
Last month
0
checked on Jun 27, 2023

Page view(s)

253
Last Week
2
Last month
checked on Jun 30, 2025

Google ScholarTM

Check

Altmetric

Altmetric

Related Items in TAIR


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Explore by
  • Communities & Collections
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Build with DSpace-CRIS - Extension maintained and optimized by Logo 4SCIENCE Feedback