標題: Control measure implications of COVID-19 infection in healthcare facilities reconsidered from human physiological and engineering aspects
作者: Yang, Ying-Fei
Lin, Yi-Jun
You, Shu-Han 
Lu, Tien-Hsuan
Chen, Chi-Yun
Wang, Wei-Min
Liao, Chung-Min
關鍵字: COVID-19;SARS-CoV-2;Wells-Riley model;Airborne infection transmission;Healthcare facility;Indoor air quality
公開日期: 22-十二月-2022
出版社: SPRINGER HEIDELBERG
來源出版物: ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH
摘要: 
The Wells-Riley model invokes human physiological and engineering parameters to successfully treat airborne transmission of infectious diseases. Applications of this model would have high potentiality on evaluating policy actions and interventions intended to improve public safety efforts on preventing the spread of COVID-19 in an enclosed space. Here, we constructed the interaction relationships among basic reproduction number (R-0) - exposure time - indoor population number by using the Wells-Riley model to provide a robust means to assist in planning containment efforts. We quantified SARS-CoV-2 changes in a case study of two Wuhan (Fangcang and Renmin) hospitals. We conducted similar approach to develop control measures in various hospital functional units by taking all accountable factors. We showed that inhalation rates of individuals proved crucial for influencing the transmissibility of SARS-CoV-2, followed by air supply rate and exposure time. We suggest a minimum air change per hour (ACH) of 7 h(-1) would be at least appropriate with current room volume requirements in healthcare buildings when indoor population number is < 10 and exposure time is < 1 h with one infector and low activity levels being considered. However, higher ACH (> 16 h(-1)) with optimal arranged-exposure time/people and high-efficiency air filters would be suggested if more infectors or higher activity levels are presented. Our models lay out a practical metric for evaluating the efficacy of control measures on COVID-19 infection in built environments. Our case studies further indicate that the Wells-Riley model provides a predictive and mechanistic basis for empirical COVID-19 impact reduction planning and gives a framework to treat highly transmissible but mechanically heterogeneous airborne SARS-CoV-2.
URI: http://scholars.ntou.edu.tw/handle/123456789/23682
ISSN: 0944-1344
DOI: 10.1007/s11356-022-24815-7