Skip navigation
  • 中文
  • English

DSpace CRIS

  • DSpace logo
  • Home
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
  • Explore by
    • Research Outputs
    • Researchers
    • Organizations
    • Projects
  • Communities & Collections
  • SDGs
  • Sign in
  • 中文
  • English
  1. National Taiwan Ocean University Research Hub
  2. 生命科學院
  3. 食品科學系
Please use this identifier to cite or link to this item: http://scholars.ntou.edu.tw/handle/123456789/9795
Title: Development and validation of an analytical procedure for quantitation of surfactants in dishwashing detergents using ultra-performance liquid chromatography-mass spectrometry
Authors: Wu, Hsin-Yi
Shih, Chia-Lung
Lee, Ton
Chen, Tai-Yuan 
Lin, Lan-Chi
Lin, Kuan-Yu
Chang, Hui-Chuan
Chuang, I-Chi
Liou, Shih-Yuan
Liao, Pao-Chi
Keywords: NONIONIC SURFACTANTS;NONYLPHENOL;EXTRACTION;MIXTURES;POLLUTANTS;TOXICITY;SULFATE
Issue Date: 1-Mar-2019
Publisher: ELSEVIER
Journal Volume: 194
Start page/Pages: 778-785
Source: TALANTA
Abstract: 
The detection of surfactants in dishwashing detergents is challenging because the detergents tend to create a lot of foam. The aim of this study was therefore to develop a simple and robust procedure for simultaneous identification and quantification of multiple surfactants in dishwashingdetergents using standard addition method and ultra-performance liquid chromatography-mass spectrometry (UPLC-MS). The results contain the method validation for 11 surfactants (linear alkylbenzene sulfonates, PPG-9-ethylhexeth-5, sodium lauryl polyoxyethylene ether sulfate, alkyl polyglucoside, sodium C14-16 olefin sulfonate, cocamide diethanolamine, cocamide monoethanolamine, lauryldimethylamine oxide, cocamidopropyl betaine, nonylphenol, and nonylphenol ethoxylate). The correlation coefficients of the linear calibration curves were larger than 0.98. The limits of detection and quantification were in the ranges of 0.43-8.0 mu g/mL and 1.42-26.4 mu g/mL, respectively. The precision ranged from 1.72% to 11.70%. The recoveries were within the range of 84-115%. The validation criteria were fulfilled for the 11 tested surfactants. The analytical procedure was applied to the analysis of 20 dishwashing detergent products collected from markets. The surfactants labeled on 13 out of the 20 products were consistent with the test results. Two surfactants, nonylphenol and nonylphenol ethoxylate, are relatively toxic to aquatic plants, fish, and aquatic invertebrates. These two surfactants were not detected among the 20 dishwashing detergent products, indicating that they were likely not added to the dishwashing detergent products. The developed UPLC-MS-based analytical procedure can be effectively applied to surfactant identification and quantification in dishwashing detergent products.
URI: http://scholars.ntou.edu.tw/handle/123456789/9795
ISSN: 0039-9140
DOI: 10.1016/j.talanta.2018.10.084
Appears in Collections:食品科學系
11 SUSTAINABLE CITIES & COMMUNITIES

Show full item record

WEB OF SCIENCETM
Citations

8
Last Week
0
Last month
0
checked on Jun 27, 2023

Page view(s)

203
Last Week
0
Last month
1
checked on Jun 30, 2025

Google ScholarTM

Check

Altmetric

Altmetric

Related Items in TAIR


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Explore by
  • Communities & Collections
  • Research Outputs
  • Researchers
  • Organizations
  • Projects
Build with DSpace-CRIS - Extension maintained and optimized by Logo 4SCIENCE Feedback